PPP > Wakeup-On-Call Examples
Example 1 Determine if Router Support Incoming Calls and Caller ID
1. On the PPP > PPP Configuration screen, make sure that PPP is Disabled.
2. On the PPP > Wakeup-on-Call screen, make sure that Wakeup-on-Call is Disabled.
3. Open a command prompt by clicking the Start button and selecting Run.
4. Type CMD to open the command window. Click OK.
5. When the command window opens, telnet to the router.
Note: 5000 is the router port number.
a. Enter your username and password to login.
b. Enter an AT command to make sure you receive a response, for example, OK.
c. On HSPA models, enter the Command AT+CNUM to determine the dial number of your router.
6. From another phone, call your router using the number identified in Step 5.3. This will let you know if the
RING message shows.
7. To enable Caller ID, enter the AT+CLIP=1 command on the command screen and make the call again to see if
it shows Caller ID information.
Notes:
Step 5c must show the RING or CALLER ID information in order for the Wakeup-on-Call function to
work.
Some wireless providers might not provide caller ID information if you have only a data plan.
Example 2 Set Up the Ethernet Router to Activate on ALL Incoming Calls
1. On the PPP >PPP Configuration screen, set up the following parameters and click Submit.
PPP General
Make sure that PPP is enabled.
Make sure Dial-on-Demand is enabled.
Set the Idle Time Out to the number of seconds you desire.
Authentication
Your wireless service provider may require you to have a separate PPP Use name and Password. If so,
enter them here.
Note: If a username and password are required, your wireless provider would have given them to you when
you activated your account.
Modem Configuration
Make sure your Dial Number is entered correctly, for HSPA models, the Dial Number is *99***1#
2. On the PPP > Wakeup-on-Call screen, set up the following parameters and click Submit.
Wakeup-on-Call Configuration
Select Enable for Wakeup-on-Call.
Set the Time Delay to 3 seconds. You can use the 10 second default.