Multitech MVP 800 Specifications Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 153
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
Chapter4–ConfiguringYourMultiVOIP
56 MultiVOIP®Voice/FaxoverIPGateways
DIDParameters
TheparametersapplicabletotheDirectInwardDial(DID)telephonyinterfacetypeareshowninthefigurethat
followsanddescribedinthetablethatfollows.The–SSand–FXmodelsdonotsupportDID.
TheDIDinterfaceallowsonephonelinetodirectincomingcallstoanyoneof
severalextensionswithouta
switchboardoperator.Ofcourse,oneDIDlinecanhandleonlyonecallatatime.Theparametersapplytothe
customer‐premisessideoftheDIDconnection(DID‐DPO,dial‐pulseoriginating).ThenetworksideoftheDID
connection(DID‐DPT,dial‐pulseterminating)isnotsupported.
DIDInterfaceParameterDefinitions
FieldName Values Description
Interface DID‐DPO Enablesthecustomer‐premisessideofDIDfunctions
DIDOptions MultiVOIP’suseofDIDappliesonlyforincomingDIDcalls.TheStartMode
usedbytheMultiVOIPmustmatchthatusedbytheoriginatingtelephony
equipment;elseDIDcallscannotbecompleted.
StartModes ImmediateStart,
WinkStart,
DelayDial
ForImmediateStart,theVOIPdetectstheoff‐hookconditioninitiatedby
thetelcocentral‐officecallandbecomesreadytoreceivedialdigits
immediately.
ForWinkStart,theVOIPdetectstheoff‐hookcondition.ThentheVOIP
reversesbatterypolarity
foraspecifiedtime(140‐290ms;a“wink”)and
thenbecomesreadytoreceivedialdigits.
ForDelayDial,theVOIPdetectstheoff‐hookcondition.ThentheVOIP
reversesbatterypolarityforaspecifiedtime(reversepolaritydurationhas
wideracceptablerangethanforWinkStart)andthenbecomesreadyto
receivedialdigits.
WinkTimer
(inms)
Integervalues,
inmilliseconds
ThisisthelengthofthewinkforWinkStartandDelayDialsignalingmodes.
ApplicableonlywhenStartModeparameterissetto“WinkStart”or“Delay
Dial.”
DialingOptions
InterDigitTimer Integervalues,
inseconds
ThisisthelengthoftimethattheMultiVOIPwaitsbetweendigits.Whenthe
timeexpires,theMultiVOIPlooksinthephonebookforthenumberentered.
Default=2.
MessageWaiting
Indication
‐‐ NotapplicabletoDID‐DPOinterface.
Inter‐Digit
RegenerationTimer
Integervalues,
inmilliseconds
Thisparameterisapplicablewhendigitsaredialedontoa DID‐DPOchannel
aftertheconnectionhasbeenmade.Thelengthoftimebetweenthe
outputtingofDTMFdigits.
Default=100ms.