Chapter2InstallingandCablingtheMultiVOIP
12 MultiVOIP®Voice/FaxoverIPGateways
c. ForaDIDconnection.
(DIDExample:DIDfaxsystemorDIDvoicephoneli nes)
ConnectoneendofanRJ11phonecordtotheChannel1FXS/FXOconnectoronthebackofthe
MultiVOIP.ConnecttheotherendtotheDIDjack.
Note:DIDlinesarepolarity
sensitive.IftheDIDlineringsbusyconsistentlyduringtesting,youneedto
reversethepolarityofoneendoftheconnector(swapthewirestothetwomiddlepinsofoneRJ11
connector).
4. Repeattheabovesteptoconnecttheremainingtelephoneequipmenttothesecondchannelonyour
MultiVOIP.
5. Ensurethattheunitisproperlyconnectedtoearthgroundbyverifyingthatitisreliablygrou ndedwhen
mountedwithinarack.Thiscanbeaccomplishedbyconnectingagroundingwirebetweenthechassisanda
metallicobjectthatprovidesanelectricalground.
6. TurnonpowertotheMultiVOIPbyplacingtheON/OFFswitchonthebackpaneltotheONposition.Wait
fortheBOOTLEDontheMultiVOIPtogooffbeforeproceeding.Thismaytakeafewminutes.
7. InstalltheMultiVOIPsoftware,asdescribedinalaterchapterinthisguide.