Multitech MVP 800 Specifications Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 153
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
Chapter3–InstallingSoftware
MultiVOIP®Voice/FaxoverIPGateways 27
b. CompleteDisconnectfields:
• CurrentReversal(usecurrentreversaltodisconnect)
• CurrentLoss(lossofcurrenttriggersdisconnect)
• CurrentLossTimer(timeaftercurrentlosstodisconnect;inmilliseconds)
• SilenceDetectionEnable(usesilencedetectiontodisconnect)
• SilenceDetectionType(one‐wayortwo‐way)
• SilenceTimer(timeofsilenceneededtotriggerdisconnect;inseconds)
• DTMFTone(usetonestodisconnect)
• DisconnectToneSequence(selecttonepairstousefordisconnecting)
• ToneDetection(disconnectfromterminationofton e)
• AvailableTones
• DisconnectTones(showscurrentselectionfromAvailableTones)
12. IntheE&MOptionsgroup(notsupportedby–SSand–FXseries):
● IntheSignalgroup,selectDialToneorWink.
● InWinkTimerfield,typeatype,whoserangecanbe100to350milliseconds;defaultis250.
● FromtheTypedrop‐downlist,selectTYPE1orTYPE11.
● IntheModegroupselect2‐wireor4‐wire.
● IntheNoResponseTimerfieldtypethetime,inseconds,afterwhichanFXOcallisdisconnected.
● CheckDisconnectonCallProgressToneifyouwanttodisconnectwhenPBXissuescallprogresstone.
13. InthePassThroughOptionsgroupselectEnabletocreateanopenaudiopatch;notforusewithWink
signaling.
14. IntheDIDOptionsgroup:(notsupportedby–SSand–FXseries)
● FromStartModesdrop‐downlist,selectImmediate,WinkorDelayDial.
● IntheWinkTimerfieldtypetime,inmilliseconds.
Page view 26