Chapter 10 – Network Service Commands
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C) 53
Notes:
The CCED response format is <band class>, <Channel #>, SID, NID, <Base Station P
Rev>,<Pilot PN offset>, <Base Station ID>, <Slot cycle index>, <Ec/Io>, <Rx power>, <Tx
power>, <Tx Adj>.
<band_class> values are 0 for cellular band (800 MHz) or 1 for PCS band (1900 MHz).
The value displayed for <Ec/Io> is the index of the Active set in 0.5dB steps from 0 (0dB) to 63 (-
31.5dB). For example: 0 = 0dB, 1 = 0.5dB, 2 = 1dB, … 62 = 31dB, 63 = 31.5dB. The value
displayed for <Rx power>, <Tx power>, and <Tx Adj> is in units of dBm.
If the <requested dump> parameter is not specified, the <requested dump> value from the most
recent invocation of the +CCED command with an explicit <requested dump> value will be used.
If no previous +CCED <requested dump> value is available, a value of 9 (8 and 1) will be used.
For <requested dump> 8, the information is output using the unsolicited +CSQ response. The
07.07 format of the +CSQ response is respected. Automatic snapshots are supported in idle
mode and during communication.
Either or both the +CCED and +CSQ responses are used for automatic snapshot output
depending upon the <requested dump> value at the time the snapshot activation was requested.