Multitech MULTIVOIP MVP-810 User Manual

Browse online or download User Manual for Networking Multitech MULTIVOIP MVP-810. MaxCS 7.0 Remote MultiVoIP Gateway Configuration

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Gateway Configuration

MAXCS Release 7.0 Application Note: Remote MultiVoIP Gateway Configuration Intended audience: AltiGen Authorized Partners March 4, 2014

Page 2 - Contents

Page 10 of 26 6. Select Configuration > Interface and configure these parameters: • Set Select Channel to Channel 1 • Set Interface Type to F

Page 3 - Requirements

Page 11 of 26 7. Select Phone Book > Outbound Phone Book and create an entry with the following parameters: • Check Accept Any Number • Set IP

Page 4 - Page 4 of 26

Page 12 of 26 9. Repeat the same process for extension 252 by adding a new entry where Remove Prefix is 252 and Channel Number is Channel 2. 10. U

Page 5 - Page 5 of 26

Page 13 of 26 To configure SIP-Tie Trunks, follow these steps: 1. Open the MultiVoIP configuration tool. 2. Select Configuration > Voice/Fax a

Page 6 - Page 6 of 26

Page 14 of 26 • Set Caller ID Type to BellCore • Check the Caller ID Enable check box 4. Select Configuration > Interface. 5. Click the Sup

Page 7 - Page 7 of 26

Page 15 of 26 Analog extensions behind the MVP gateway are optional. If the analog extensions are required, complete the steps in the section SIP Ex

Page 8 - SIP Extension Configuration

Page 16 of 26 5. Log into the MultiVoIP tool. 6. Select Phone Book > Inbound Phone Book and add a new entry with the following parameters: •

Page 9 - Page 9 of 26

Page 17 of 26 Outgoing Calls to PSTN Using Out Call Routing (Optional) To make a call to the outside though the MVP gateway requires dialing a numbe

Page 10 - Page 10 of 26

Page 18 of 26 To configure outgoing PSTN call via Out-call routing, follow these steps: 1. Log into MaxCS Administrator and select PBX > Trunk C

Page 11 - Page 11 of 26

Page 19 of 26 7. Select all the analog trunks (in this example, from “02:000” to “02:011”) as Member Trunks. 8. Click Apply. 9. Select PBX >

Page 12 - Page 12 of 26

Page 2 of 26 Contents Introduction ...

Page 13 - Page 13 of 26

Page 20 of 26 Verification At this point, you should be able pick up extension 104 and make an outbound call by dialing 914081231234. Outpost Digits

Page 14 - Verification

Page 21 of 26 5. Select PBX > Out Call Routing Configuration > Dialing Pattern and add a new entry: • Set Prefix to 1510 • Set Pattern len

Page 15 - Page 15 of 26

Page 22 of 26 Verification 1. Follow Figure 3. Use extension 104 to dial 15102520004. The call should go through the MVP gateway. 2. Use extension

Page 16 - Advanced Configuration

Page 23 of 26 3. Move extensions 210, 251 and 252 to the Members list. (Extensions 251 and 252 are optional if you only have AltiGen IP phone 210.)

Page 17 - Page 17 of 26

Page 24 of 26 Under Dialed Digit Translator: 1. Log into MaxCS Administrator and select System > System Configuration > Number Plan. 2. From

Page 18 - Page 18 of 26

Page 25 of 26 To configure emergency gateway dialing, follow these steps: 1. Log into the MultiVoIP configuration tool and select Phone Book > I

Page 19 - Page 19 of 26

Page 26 of 26 AltiGen Technical Support AltiGen does not provide general configuration support for EdgeWater or AudioCodes products. For general con

Page 20 - Outpost Digits

Page 3 of 26 Introduction This document provides guidelines for setting up a MultiTech gateway as a remote SIP trunking gateway, and for configurin

Page 21 - Page 21 of 26

Page 4 of 26 2. Select Configuration > Call Signaling > SIP. Set Signaling Port to 5060. 3. Select Configuration > Call Signaling > N

Page 22

Page 5 of 26 • Set Transport Protocol as UDP. • Set SIP Port Number as 5060. Enterprise Manager Configuration 1. Open Enterprise Manager and log

Page 23

Page 6 of 26 3. Add a new codec profile named MVP Gateway. Set the following parameters: • Set Codec to Prefer G.723.1 support G.729 (the codec b

Page 24

Page 7 of 26 The “Connect Voice Stream to Server” Option MaxCSIP Address10.10.0.237MVP 410AltiGen IP phoneExt 210PSTNTel 5102520004SIP SinganalingSI

Page 25

Page 8 of 26 Under the following conditions, the system administrator will need to check the Connect Voice Stream to Server option: • When the Voic

Page 26 - AltiGen Technical Support

Page 9 of 26 Follow these steps to configure the SIP extensions: 1. In MaxCS Administrator, select Extension Configuration. 2. Add two virtual ext

Comments to this Manuals