Multitech MULTIVOIP MVP-810ST User's Guide Page 259

  • Download
  • Add to my manuals
  • Print
  • Page
    / 559
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 258
MultiVOIP User Guide Technical Configuration (Analog/BRI)
259
DID Parameters. The parameters applicable to the Direct Inward Dial
(DID) telephony interface type are shown in the figure below and
described in the table that follows. The DID interface allows one phone
line to direct incoming calls to any one of several extensions without a
switchboard operator. Of course, one DID line can handle only one call
at a time. The parameters described here pertain to the customer-
premises side of the DID connection (DID-DPO, dial-pulse originating);
the network side of the DID connection (DID-DPT, dial-pulse
terminating) is not supported.
DID Interface Parameter Definitions
*Not applicable to MVP130FXS
Field Name Values Description
Interface DID-DPO Enables the customer-premises
side of DID functionality
DID Options MultiVOIP’s use of DID applies
only for incoming DID calls.
The Start Mode used by the
MultiVOIP must match that
used by the originating
telephony equipment, else DID
calls cannot be completed.
Start Modes Immediate Start,
Wink Start,
Delay Dial
For Immediate Start, the voip
detects the off-hook condition
initiated by the telco central-
office call and becomes ready to
receive dial digits immediately.
Page view 258
1 2 ... 254 255 256 257 258 259 260 261 262 263 264 ... 558 559

Comments to this Manuals

No comments