S-Registers for the MT5656ZDX, MT5600ZDX, MT5600BA/BL-Series Modems
50
Multi-Tech Systems, Inc. Commands Reference Guide (PN S000273D)
V.92 S-Registers
Certain modem values, or parameters, are stored in memory locations called S-registers. Use the S command to
read or alter the contents of S-Registers. See the MT5600BA/BL–V.90 S-Registers Section for S-Registers that apply
the V.90 only.
Register Unit Range Default Description
S0 1 ring 0, 1–255 country dep. Number of Rings to Auto-Answer: Sets the number of rings required
before the modem automatically answers a call. ATS0=0 disables
autoanswer completely.
S1 1 ring 0–255 0 Ring Counter: Counts the rings that have occurred.
S2 decimal 0–127 43 (+) Escape Character: Sets ASCII code for the escape sequence
128–255 character. Values greater than 127 disable escape.
S3 decimal 0–127 13 (^M) Carriage Return Character: Sets the ASCII code for the carriage return
character.
S4 decimal 0–127 10 (^J) Line Feed Character: Sets the ASCII code for the line feed character.
S5 decimal 0–32 8 (^H) Backspace Character: Sets the ASCII code for the backspace
33–127 character. Values greater than 32 disable backspace.
S6 seconds 2–255 country dep. Wait Time Before Blind Dialing or for Dial Tone: Sets the time the
modem waits after it goes off-hook before it begins to dial the phone
number.
S7 seconds 1–255 country dep. Wait Time for Carrier, Silence, or Dial Tone: Sets the time the modem
waits for a carrier signal before aborting a call. Sets the wait for silence
time for the @ dial modifier. Sets the time the modem waits for a dial tone
after encountering W in the dial string.
S8 seconds 0–255 2 Pause Time for Dial Delay: Sets the length of the pause caused by a
comma character in a dialing command.
S9 100 ms 1–255 6 Carrier Detect Response Time: Sets the time, in tenths of a second,
that the carrier must be present before the modem considers it valid.
S10 100 ms 1–255 14 Lost Carrier to Hang Up Delay: Sets how long a carrier signal must be
lost before the modem disconnects.
S11 1 ms 50–255 country dep. DTMF Tone Duration: Sets spacing and duration of dialing tones.
S12 20 ms 0–255 50 Escape Prompt Delay (EPD): Defines the maximum period, in fiftieths of
second, allowed between receipt of the last character of the three
escape character sequence from the computer and the sending of the
OK result code to the computer (escape code guard time).
S13 decimal 0, 1–127 42 (*) Remote Configuration Escpae Character: Sets the ASCII code for the
remote configuration escape character. ATS13=0&W disables remote
configuration.
MT5600BA/BL-V.92 and V.90 only.
S15 minutes 0, 10–255 30 Dialup Backup: Sets the length of time the modem waits after making a
dial-up connection before it checks the lease line for restoral. Zero
disables dial backup.
MT5600BA-V.92 only.
MT5600BA V.92 LCD:
S17 minutes 0–255 1 Dialup Connection: Sets the length of time the modem waits after a
lease line fails before it attempts a dial-up connection. MT5600BA-V.92