Multitech GFU19 User Manual Page 180

  • Download
  • Add to my manuals
  • Print
  • Page
    / 226
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 179
180TPS1200
Technical Data
7.6 PowerSearch PS
Range
Measurements at the vertical limits of the fan or under unfavourable atmospheric
conditions may reduce the maximum range. (*aligned to the instrument optimal)
Shortest
measure distance
Searching
Characteristics
Reflector Range PS
[m] [ft]
Standard prism 200 650
360° prism 200* 650*
Mini prism 100 330
360° prism: 5 m
Typical search time: <10 s
Default search area: Hz: 400 gon, V: 40 gon
Definable search windows: Yes
Principle: Digital signal processing