Radio Modem Setup
SW2.1 = OFF :1200 baud
SW2.2 = OFF
SW2.3 = ON
SW2.4 = OFF :Parity Disable
SW2.5 = OFF
SW2.6 = ON :8 Bits
SW2.7 = OFF
SW2.8 = OFF :1 Bit
Set SW1.1 to OFF (This captures the settings of the other switches into memory).
Without moving SW1.1 set all the other switches to OFF
The modem now requires to have its individual address and channel number set.
This must be done without moving switch SW1.1
RF channels are set on SW1.4 to SW1.8 as a binary code indicating the channel Number. SW1.4 is the
least significant bit. Channel numbers are in the range 0 to 31.
Unit addresses are set on SW2.1 to SW2.8 as a binary code indicating the unit address. SW2.1 is the least
significant bit. Addresses are in the range 0 to 255.
NMCS2 Protocol
For NMCS2 protocol the base station and the outstations are set the same. The Modem software for both
the base station and the outstation is the standard RDT software version 2.2 or above.
Power up the modem
Set all the DIP switches to OFF
Set SW1.1 = ON
Set the following switched as indicated
SW1.2 = OFF : Async Mode
SW1.3 = OFF