DATE:
SIGNAL ENGINEERING
DOT
DRAWN:
DWG
NO.
SHEET
M.P.
OF
REVISIONS
P.O. BOX 107500, ANCHORAGE, AK 99510-7500
NORTH "C" STREET
ANCHORAGE, AK.
114.40
868 535 Y
S5.3
3
17
02-02-07
THE MINIMUM PROGRAM STEPS REPORT IS GENERATED BY USING
SAFETRAN’S DIAGNOSTIC TERMINAL SOFTWARE SUITE AND IS NOT A
COMPLETE PROGRAM LIST FOR THE SETUP AND/OR CUTOVER OF ANY
GCP 4000 UNIT. IT IS MISSING THE CALIBRATION SEQUENCE FOR THE
TRACK CIRCUITS AND SIGNALS CONNECTED TO THE UNIT IN THE FIELD
APPLICATION. THE CUSTOMER SHOULD REFER TO THE GCP 4000
REFERENCE MANUAL SECTION 6 FOR THE PROPER CALIBRATION OF
ALL TRACK CIRCUITS AND SIGNALS CONNECTED TO THE UNIT. THE
ALASKA RAILROAD CORPORATION SHALL BE RESPONSIBLE FOR SITE
SPECIFIC SETTINGS AND PROGRAMMING TO MEET THE LOCATION
REQUIREMENTS FOR TESTING AND CUTOVER OF ANY SPECIFIC
THE TRANSMITTER AND RECEIVER LEADS - MUST BE 120’ MINIMUM.
FOR ISLAND DISTANCE MEASURE THE DISTANCE BETWEEN
CLOSED
8
MIN.
16
OPEN
24 1
ON MODULE A80468
SET TRANSFER JUMPER TO STG.
SET TRANSFER TIME FOR 4 MIN.
SET TRANSFER SWITCH TO AUTO.
CROSSING.
2.)
3.)
S3
1.)
NOTES:
02-02-07
DSD
TMJ
SHIP CREEK INTERMODAL
TRANSPORTATION CENTER
DESIGNED
TRACK-6
TRK TRKTRKTRKTRK
CPU
CALL
SYNC
FLASH
-
+
MAINT
N
B
N
A80418
TRACK-1
XMT1
XMT2
TRK
CHK2
RCV2
CHK1
TRK
A80418
TRACK-2
XMT2
CHK2
CHK1
XMT1
RCV2
TRK
TRK
A80418
TRACK-3
RCV2
XMT1
CHK1
CHK2
XMT2
TRK
TRK
TRACK-4
A80418
CHK1
RCV2
CHK2
XMT2
XMT1
TRK
TRK
A80418
TRACK-5
TRK
TRK
XMT1
XMT2
RCV2
CHK2
CHK1
OUT1.1
LONTALK
PROTOCAL
DIAG
B
ECH
RCV1
IN1.2
IN1.1
+
-
+
-
OUT1.2
+
-
-
ECH
+
OUT2.1 OUT3.1
RCV1
-
+
(POK)
SP2.1
+
-
-
+
+
-
-
IN2.2
IN2.1
OUT2.2
SP3.1
(DOOR)
RCV1
-
+
OUT3.2
IN3.1
IN3.2
-
+
+
-
+
-
-
+ +
OUT5.1OUT4.1
SP4.1
RCV1
-
+
OUT4.2
IN4.1
IN4.2
-
+
+
-
+
-
-
SP5.1
RCV1
+
-
IN5.1
OUT5.2
IN5.2
+
-
+
-
-
+
-
+ +
IN8.1IN7.1
TRK
SAFETRAN
A80405
SSCC-1
A80418
TRK
TRK
XMT1
XMT2
RCV2
CHK2
CHK1
(GP)
IN7.5
-
+
+
IN7.3
IN7.4
(GD)
(GP)
+
-
-
(GD)
IN7.2
-
-
+
A80405
SSCC-2
(GP)
IN8.5
+
-
IN8.3
+
(GD)
IN8.4
(GP)
+
-
-
(GD)
IN8.2
-
+
-
A80460
NN
BB
1L1
1L2
OUT6.1
RCV1
-
+
SP6.1
OUT6.2
+
-
+
-
IN6.2
IN6.1
+
-
-
+
1 GC
-
+
CAUTION
WARNING
ASSURE CORRECT POLARITY OR
REMOVING INPUT POWER FROM
LIGHTS WILL NOT ACTIVATE.
GATE(S) TO DROP BUT THE
THE SSCC WILL CAUSE THE
SEVERE DAMAGE WILL OCCUR
1 BELL
+
NN
B
2L1
2L2
B
+
2 GC
-
+
2 BELL
CAUTION
WARNING
SEVERE DAMAGE WILL OCCUR
ASSURE CORRECT POLARITY OR
LIGHTS WILL NOT ACTIVATE.
GATE(S) TO DROP BUT THE
THE SSCC WILL CAUSE THE
REMOVING INPUT POWER FROM
ALL NEW
SSCC: 1
SSCC 1 : Flash Rate = 55
SSCC: 2
SSCC 2 : Flash Rate = 55
IO: assignment SSCC
OUT GC 2 = Not Used
SEAR
DI 1 = Gnd Flt Tester 1
Rly 1 = Ground Fault Test
Rly 2 = AC Control
SEAR: slot 1-4 inputs
IN 2.2 = POK 2
SEAR: slot 7-8 inputs
IN 7.2 = TSS 1
IN 7.4 = TSS 2
Office Configuration Check Number
---------------------------
Check Number: 1505723C
(Based on MCF Revision 012)
Comments
---------------------------
<none>
Configuration Package File
---------------------------
Filename: Config-868535Y.pac
Date/Time: 2/02/2007 8:45:50
TEMPLATE: AND 1 XR
AND 1 XR Track 4 = Not Used
AND 1 Enable Used = Yes
TEMPLATE: SSCC
SSCC-1 Number of GDs = 0
TEMPLATE: OP assignment 1
OUT 3.1 = T4 Prime
TEMPLATE: IP assignment 1
IN 1.1 = AND 1 XR Enable
IN 3.1 = AND 1 XR Enable
TEMPLATE: IP assignment SSCC
IN 7.2 = Not Used
IN 7.4 = Not Used
TEMPLATE: SEAR
SP 3.1 = Not Used
BASIC: island operation
Track 4 : Island Used = No
GCP: track 1
Track 1 : Island Distance = 132 ft
GCP: track 2
Track 2 : Island Distance = 132 ft
GCP: track 3
Track 3 : Island Distance = 132 ft
GCP: track 4
Track 4 : Uni/Bi/Sim-Bidirnl = Unidirnl
Track 4 : Island Connection = No Islands
Track 4 : Island Distance = 0 ft
GCP: track 4 prime
Track 4 : Prime Offset Distance = 1183 ft
Track 4 : Pickup Delay Mode = Auto
ADVANCED: out of service
OOS Timeout = No
ADVANCED: site options
Daylight Savings = On
Minimum Program Steps Report
---------------------------
Location and SIN
---------------------------
DOT Number: 868535Y
Milepost Number: 114.40
Site Name: NORTH C STREET
SIN: <NOT SET>
MCF and Template Selection
---------------------------
MCF Name: GCP-T6X-01-2.mcf
MCF Revision: 012
MCFCRC: 0DFE7A0C
Template = 1A:6 Trk Bi
Minimum Program Steps
---------------------------
TEMPLATE: module configuration
Track 2/RIO 1 Slot = Track
Track 3 Slot = Track
Track 4 Slot = Track
TEMPLATE: track 1-Bi, Island
Track 1 : GCP Frequency = 348 Hz
Track 1 : Approach Distance = 1892 ft
Track 1 : Prime Warning Time = 38 sec
Track 1 : GCP Transmit Level = Medium
Track 1 : Isl Frequency = 5.9 kHz
TEMPLATE: track 2-Bi, Island
Track 2 : GCP Frequency = 348 Hz
Track 2 : Approach Distance = 1577 ft
Track 2 : Prime Warning Time = 38 sec
Track 2 : GCP Transmit Level = Medium
Track 2 : Isl Frequency = 4.9 kHz
TEMPLATE: track 3-Bi, Island
Track 3 : GCP Frequency = 430 Hz
Track 3 : Approach Distance = 1577 ft
Track 3 : Prime Warning Time = 38 sec
Track 3 : GCP Transmit Level = Medium
Track 3 : Isl Frequency = 4.0 kHz
TEMPLATE: track 4-Bi, Island
Track 4 : GCP Frequency = 645 Hz
Track 4 : Approach Distance = 1000 ft
Track 4 : Prime Warning Time = 33 sec
Track 4 : GCP Transmit Level = Medium