CHAPTER 3 SPECIFICATIONS
15
SocketModem EV-DO MTSMC-EV3 Device Guide
Radio
Protocol
Instant Peak TX
Current (Amps)
Total Inrush Charge
measured in Coulombs
Inrush Duration (Total
Inrush charge duration
during powerup).
3.3 Volts
US Cellular
1.056
15.37mC
1.84ms
PCS
1.276
15.37mC
1.84ms
EV-DO
1.12
15.37mC
1.84ms
5 Volts
US Cellular
0.664
15.37mC
1.84ms
PCS
0.752
15.37mC
1.84ms
EV-DO
0.644
15.37mC
1.84ms
Notes:
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a transmission burst period or connection. This current is handled by
bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Charge: The total inrush charge current amplitude at power on.
MTSMC-EV3-MI-GP
Radio
Protocol
AT
command
used to set
radio
function and
power mode
Connection
No Data
(Amps)
Half Power
Max Power
Average
Measured
Current
(Amps)
Output
Power
Level
Ch Power
Meas.
(Avg)
Average
Measured
Current
(Amps)
Output
Power
Level
Ch Power
Meas.
(Avg)
3.3 Volts
US Cellular
AT+CFUN=1
0.270
0.412
-13
-60
1.000
22
-97
PCS
AT+CFUN=1
N/A
0.395
-16
-60
1.151
20
-99
EV-DO
AT+CFUN=1
0.240
0.414
-25
-70
0.928
21
-96
5 Volts
US Cellular
AT+CFUN=1
0.173
0.270
-13
-60
0.660
22
-95
PCS
AT+CFUN=1
N/A
0.260
-16
-60
0.696
21
-60
EV-DO
AT+CFUN=1
0.161
0.267
-25
-70
0.565
23
-70
Note: This data is measured using an Agilent call box connected to the cellular radio.