CHAPTER 3 SPECIFICATIONS
13
SocketModem EV-DO MTSMC-EV3 Device Guide
Radio
Protocol
Instant Peak TX
Current (Amps)
Total Inrush Charge
measured in Coulombs
Inrush Duration (Total Inrush Charge
duration during powerup).
3.3 Volts
US Cellular
0.956
17.70mC
1.90ms
PCS
1.084
17.70mC
1.90ms
EV-DO
0.744
17.70mC
1.90ms
5 Volts
US Cellular
0.608
17.77mC
1.74ms
PCS
0.696
17.77mC
1.74ms
EV-DO
0.496
17.77mC
1.74ms
Notes:
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a transmission burst period or connection. This current is handled by
bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Charge: The total inrush charge current amplitude at power on.
MTSMC-EV3-U
Radio
Protocol
AT
command
used to set
radio
function and
power mode
Connection
No Data
(Amps)
Half Power
Max Power
Average
Measured
Current
(Amps)
Output
Power
Level
Ch Power
Meas.
(Avg)
Average
Measured
Current
(Amps)
Output
Power
Level
Ch Power
Meas.
(Avg)
3.3 Volts
US Cellular
AT+CFUN=1
0.062
0.220
-13
-60
0.845
22.7
-96.2
PCS
AT+CFUN=1
N/A
0.201
-16
-60
0.878
21
-99.1
EV-DO
AT+CFUN=1
0.057
0.218
-26
-70
0.690
23
-96
5 Volts
US Cellular
AT+CFUN=1
0.056
0.146
-13
-60
0.521
22
-60
PCS
AT+CFUN=1
N/A
0.133
-16
-60
0.541
22
-99
EV-DO
AT+CFUN=1
0.043
0.145
-25
-70
0.436
22
-96
Note: This data is measured using an Agilent call box connected to the cellular radio.