Chapter 2 – Modem-Specific Commands
High Speed HSPA-H4 AT Commands Reference Guide (Document S000483A) 25
!PCVOLT Return Current Power Supply Voltage Information
Syntax: Query: AT!PCVOLT?
Response: Volt state: Normal
Power supply voltage: <voltage> mV (<raw> cnt)
OK
Purpose: Return the module’s voltage information.
Description: Return the module’s power supply state and actual voltage.
Parameters: <state> (Power supply state):
Valid values:
“Normal”
“High Critical”
“Low Warning”
“Low Critical”
<voltage>:
Current voltage reading in mV.
<raw>:
Analog/Digital Convertor reading
!POWERDOWN Power Down System
Syntax: Execution: AT!POWERDOWN
Response: OK
Purpose: Power the system down.
Description: Power down the system. After using this command, the modem will not communicate with
the host until it has been power cycled.
Note: This command should only be used when testing using an appropriate testing jig—do not
use it when the modem is installed in a computer.